AC, DC Meters
DC ve AC elektrik devrelerinin izlenmesi için çeşitli akım ve gerilim sensörleri.
VT406 / DC HOS Sensor Transducer
Transducer is used together with HOS-100Q1 dc Hall current sensors and converting data into format of IP monitoring system. The system interface allows you to assign the current meter and to introduce the function data conversion.
HOS-100Q1 / DC Current Transducer
100A Hall transducer is used for measurement of DC current. The system interface allows you to assign sensor and to introduce the function data conversion. VT406 / HOS transceiver can be used together with HOS-100Q1 to convert data into format of IP monitoring system.
VT407 / AC HAT Sensor Transducer
Transducer is used together with HAT-100Q1 current transducer and transferring data into a monitoring system. The system interface allows you to assign the current meter and to introduce the function data conversion.
HAT-100Q1 / AC Current Transducer
100A transducer is used for measurement of AC current. The system interface allows you to assign transducer and to introduce the function data conversion. VT407 / HAT transceiver can be used together with HAT-100Q1 to convert data into format of IP monitoring system.
VT410 / DC Voltage Monitor
DC monitor is used for measurement of DC voltage up to 60V and converting data into format of IP monitoring system. The system interface allows you to assign the sensor and to introduce the function data conversion.
Only 6P6C RJ12 cable can be used with sensor!
Dimensions | Size 60×18×18 mm |
Weight | 100 g |
Inputs | RJ-12 / RJ-11 |
Operating characteristics | Temperature : Min. -10° C - Max.80° C, Humidity : Min. 5% - Max. 95% (Non-Condensing) |
Mounting | Desktop, Wall mount |
Power Consumption | 100 mW |
Components | Manufactured in E.U. |
Max. distance | 50 m |
HS Code | 9030 33 300 |
Special Features | Isolation - 1 kV, Measured voltage - 0..60 V, Accuracy - 1%. |
Package includes | Mounting bracket, Sensor, Nuts М4 2pcs, Screws M5 19mm 2pcs, Sticker, Terminal plug 2 pins 5mm 1pc |
VT420 / Converter 4-20mA
Converter of current loop 4-20mA is used for measurement of constant current on 4-20mA from different sensors and converting data into format of IP monitoring system. The system interface allows you to assign the sensor and to introduce the function data conversion.
Dimensions | Size 60×18×18 mm |
Weight | 60 g |
Inputs | Terminal plug 2pins 5mm |
Operating characteristics | Humidity : Min. 5% - Max. 95% (Non-Condensing) |
Outputs | RJ11 / RJ12 |
Mounting | Wall mount |
Power Consumption | 100 mW |
Components | Manufactured in E.U. |
Max. distance | 50 m |
HS Code | 9030 33 100 |
Special Features | Isolation - 1 kV, Measured current - 4-20 mA, Accuracy - 2%. |
Package includes | Terminal plug 2 pins 5mm 1pc, Sticker, Screw 1pc M5, Cable RJ11/RJ12 to RJ11/RJ12 (2m) |
VT520 / AC voltage Monitor
Sensor is needed for measurement of AC 90-250V
Dimensions | Size 63×66×40 mm |
Weight | 125 g |
Inputs | RJ-12 / RJ-11 |
Operating characteristics | Temperature : Min. -10° C - Max.80° C, Humidity : Min. 5% - Max. 95% (Non-Condensing) |
Power input | 90-240V, IEC C14 |
Mounting | Insert in the socket |
Power Consumption | 60 mW |
Components | Manufactured in E.U. |
Max. distance | 100 m |
HS Code | 9030 33 300 |
Special Features | Voltage measured - 90 .. 250 V, Accuracy - 2%. |
Package includes | Sensor, Cable RJ11/RJ12 to USB 1.8m |